Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (2024)

Objective. After decades of study in humans and animal models, there remains a lack of consensus regarding how the action of electrical stimulation on neuronal and non-neuronal elements—e.g. neuropil, cell bodies, glial cells, etc.—leads to the therapeutic effects of neuromodulation therapies. To further our understanding of neuromodulation therapies, there is a critical need for novel methodological approaches using state-of-the-art neuroscience tools to study neuromodulation therapy in preclinical models of disease. Approach. In this manuscript we outline one such approach combining chronic behaving single-photon microendoscope recordings in a pathological mouse model with electrical stimulation of a common deep brain stimulation (DBS) target. We describe in detail the steps necessary to realize this approach, as well as discuss key considerations for extending this experimental paradigm to other DBS targets for different therapeutic indications. Additionally, we make recommendations from our experience on implementing and validating the required combination of procedures that includes: the induction of a pathological model (6-hydroxy dopamine model of Parkinson's disease) through an injection procedure, the injection of the viral vector to induce GCaMP expression, the implantation of the gradient refractive index lens and stimulation electrode, and the installation of a baseplate for mounting the microendoscope. We proactively identify unique data analysis confounds occurring due to the combination of electrical stimulation and optical recordings and outline an approach to address these confounds. Main results. In order to validate the technical feasibility of this unique combination of experimental methods, we present data to demonstrate that (1) despite the complex multifaceted surgical procedures, chronic optical recordings of hundreds of cells combined with stimulation is achievable over week long periods (2) this approach enables measurement of differences in DBS evoked neural activity between anesthetized and awake conditions and (3) this combination of techniques can be used to measure electrical stimulation induced changes in neural activity during behavior in a pathological mouse model. Significance. These findings are presented to underscore the feasibility and potential utility of minimally constrained optical recordings to elucidate the mechanisms of DBS therapies in animal models of disease.

1.Introduction

A multitude of neurologic and psychiatric disorders affect up to one billion people worldwide [1], and up to 30% of the patients diagnosed with neurologic disorders remain refractory to conventional pharmacologic, behavioral, and surgical interventions [2, 3]. To address this patient population, the last 30 years have seen a significant expansion in the application of devices to electrically stimulate the nervous system for therapeutic effect, known as neuromodulation therapies, that have become established forms of treatment for patients suffering from these neurologic and psychiatric conditions. For example, electrical stimulation of deep brain structures, known as deep brain stimulation (DBS), has received approval from the United States Food and Drug Administration (FDA) for the treatment of advanced Parkinson's disease (PD), tremor [46], and epilepsy [710]. Additionally, humanitarian device exemptions have been granted for treatment of dystonia and obsessive–compulsive disorder [6]. Despite the clinical prevalence of DBS therapies, the mechanisms of action for any specific therapeutic use of DBS are poorly understood.

Studies to elucidate mechanisms of action of DBS have centered on measuring the evoked physiological responses using non-invasive functional imaging [1114] and electrophysiological recording techniques [1520]. Unfortunately, these techniques have inherent limitations that make it difficult to parse out the multimodal mechanisms by which DBS may alter the activity of a neural circuit during the execution of complex behavior. Functional imaging techniques—such as functional magnetic resonance imaging (fMRI) and positron emitted tomography (PET)—have low spatial (on the order of a millimeter) and temporal resolution (on the order of several seconds) and can only be performed during simple behavioral paradigms that restrict overall movement [21, 22]. Electrophysiological recordings from single-unit or multi-unit populations provide high spatial and temporal resolution but are limited to sparse sampling (typically under 100 electrode contacts separated by hundreds of microns), provide limited or unreliable information about recorded cell types and their exact spatial locations [23], and have low signal stability over time that limits the study of DBS induced plastic changes in circuit function [24, 25]. As DBS induces electromagnetic cross-talk and disturbs the recording electrode/electrolyte interface, electrical stimulation also generates spurious artifacts that can resemble electrophysiological responses [26, 27].

The intended therapeutic and unintended side effects of DBS are likely mediated through multiple mechanisms, potentially driven by multiple cell types, that alter the function of a neural circuit. The relative contribution of each mechanism may evolve over the course of stimulation due to changes in the electrode/tissue interface [28, 29], stimulation induced plasticity in neuronal and non-neuronal cells near the electrode [30], stimulation induced post-synaptic plasticity [31], changes in behavior state [32], and adjunct drug status [33]. Clinical use of neuromodulation therapies in diverse conditions such as epilepsy, depression and Tourette's syndrome consistently demonstrate significant improvement in patient outcomes with slow onsets over periods of several weeks to several months [11, 3442]. Whether these slow therapeutic responses are a result of placebo effect, changes to tissue local to the implant, wider network adaptation, or combinations of all the above, remains unknown. Consequently, experimental paradigms for elucidating the therapeutic mechanisms of DBS ideally need to be able to record from stable populations of hundreds of genetically specified cells with high spatial and temporal resolution across timeframes of weeks to months. These measurements need to be made during behaviors relevant to the clinical indication being studied to understand the role of both the local, circuit, and systems level dependencies in the neural response to DBS.

Single-photon calcium imaging via a head-mounted miniature microscope has previously been demonstrated in behaving animals to record from large stable populations of genetically specified cells across timeframes of weeks to months [4346] but has yet to be extended to the study of neuromodulation therapies. Towards that end, here we introduce our method for combining electrical stimulation of deep brain structures with chronic single-photon imaging in a behaving mouse with induced disease pathology (figures 1(A), (B)). Combining single-photon microscopy in a pathological model of DBS adds several invasive components to the experimental procedure, which introduce more potential failure points. Consequently, we provide recommendations from our experience in implementing this combination of methods on how to separately refine and validate each component step to achieve a combined procedure. As synchronous neural activity evoked by electrical stimulation confounded some state-of-the-art miniature microscopy analysis techniques, we present a qualitative assessment of different analysis techniques to underscore the importance validating the accurate identification of neuronal calcium traces in the context of neuromodulation. As the integration of these multiple complex components may impact recording quality, we provide data to verify the technical feasibility of maintaining stable optical recordings of hundreds of striatal cells for week long periods in the 6-hydroxy dopamine (6-OHDA) mouse model of Parkinson's Disease also implanted with electrodes to provide stimulation to the subthalamic nucleus (figure 1(C)). We also present our initial within-animal findings that subthalamic nucleus (STN) stimulation evoked responses significantly differ as a function of anesthetized versus awake states, as well as between rest versus movement in the awake state. These initial data illustrate the need for studying DBS mechanisms in awake, behaving pathological models. Whether these within-animal differences elucidate fundamental mechanisms of DBS therapies across a cohort will be explored in future studies.

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (1)

2.Methods

The experimental protocol to obtain calcium imaging in a behaving 6-OHDA lesioned mouse with electrical stimulation required the successful implementation of four separate components: (1) induction of calcium indicator expression via a unilateral injection of an AAV9 viral vector into striatum (figures 2(A), B), (2) placement of a gradient refractive index (GRIN) lens into the target recording location just above striatum (figures 2(A), C), (3) induction of a parkinsonian phenotype via unilateral injection of 6-OHDA into the substantia nigra pars compacta (SNc) (figures 2(A), (B)), and (4) placement of a bipolar stimulating electrode within the STN for application of electrical stimulation (figures 2(A), (C). Each component of this experimental protocol was first tested in isolation in order to minimize the time and troubleshooting needed to implement the complete experiment.

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (2)

2.1.Subjects

In total 30 adult C57BL/6 J male mice approximately 25–30 g (Jackson Laboratories, Bar Harbor, ME) were used to test each component of the experimental protocol. These animals were used for verifying 6-OHDA lesioning and behavior (n = 15, only shown in supplementary data available online at stacks.iop.org/JNE/18/026008/mmedia), and chronic recordings in healthy mice and parkinsonian mice (n = 5 and n = 10, respectively). Of the ten parkinsonian mice, four were removed from analysis due to surgical complications and implant/expression issues while the others were used for data collection while under anesthesia (n = 6). Two these six animals in which anesthetized recordings were performed were removed from the analyses presented here, as post-mortem histology indicated their electrodes were not properly placed within STN. Awake calcium imaging studies were also performed in two of these animals. Exclusion criteria and experimental outcomes are described in table 1.

Table 1. Animal outcomes. Outcomes of animal cohorts used to validate chronic calcium imaging within the mouse dorsal striatum and for the total experimental procedures including AAV9 injections to induce GCaMP6m expression (figure 2(A)), combined with placement of a GRIN lens (figure 2(B)), 6-OHDA lesioning (figure 2(A)), and placement of bipolar stimulating electrodes (figure 2(B)).

AnimalCohort (striatum imaging/total)Exclusion reasonStimulation amplitude (anesthetized)Stimulation amplitude (awake behaving)
M1Striatum imagingNANANA
M2Striatum imagingNANANA
M3Striatum imagingNANANA
M4Striatum imagingNANANA
M5Striatum imagingNANANA
M6TotalSurgical complicationsNANA
M7TotalElectrode located outside of STNNANA
M8TotalInsufficient GCaMP expression for imagingNANA
M9TotalNA130 µANA
M10TotalNA180 µANA
M11TotalSurgical complicationsNANA
M12TotalLens damage preventing imagingNANA
M13TotalElectrode located outside of STNNANA
M14TotalNA150 µA30 µA
M15TotalNA220 µA80 µA

Animals were group-housed and maintained under a standard light/dark cycle with ad libitum access to food and water. All experimental procedures were approved by the either the Mayo Clinic Institutional Animal Care and Use Committee (IACUC) or the IACUC at LifeSource Biomedical Services, NASA Ames Research Center, California and were carried out in accordance with the U.S. National Research Council Guide for the Care and Use of Laboratory Animals.

2.2.Injection of viral vector and dopaminergic lesioning

Mice were anesthetized in an induction chamber with 5% isoflurane (inhalation) and then maintained with a continuous flow of 1%–2% isoflurane-oxygen mixture during stereotactic surgery (Kopf Systems, Tujunga, CA). A midline incision was performed to expose the skull and burr holes were made above the dorsal striatum (ML = 1.65, AP = 1.0 from bregma) and substantia nigra pars compacta (SNc) (ML = 1.25, AP = –3.5 from bregma). A Hamilton syringe (Hamilton Company, Reno, NV) controlled by a stereotactically mounted microdrive (WorldPrecision Instruments) was lowered into right dorsal striatum (AP = +1.0 mm, ML = +1.65 mm, DV = −2.7 mm from dura) at an approximate rate of 10 µm s−1 and used to inject 500 nL of AAV9.CAG.GCaMP6m.WPRE.bGHpA (titer = 5.5 × 1012 GC mL−1; SignaGen Laboratories, Rockville, MD) at a rate of 100 nl min−1 (figure 2(B)). Brain tissue was given one minute to settle prior to the unilateral AAV injection. The virus was allowed to diffuse for an additional five minutes prior to removing the needle at approximately 10 µm s−1.

Immediately following AAV injection, a separate Hamilton syringe was used to inject 6-OHDA (4 µg µl−1) into the SNc at three depths: DV −4.2, −4, and −3.8 from dura (figure 2(B)). Injections at each location were 650 nL, and delivered at a rate of 100 nl min−1. At each of the three depths, the injection was preceded with a wait period of one minute to allow brain tissue to stabilize, and followed by a wait period of five minutes for diffusion [43]. Insertion, removal and movements of the injection needle were carried out at approximately 10 µm s−1. Desipramine HCl was injected (25 mg kg−1, i.p.) approximately 30 min before the first 6-OHDA injection to prevent uptake of 6-OHDA into monoamine neurons [47]. The burr holes were sealed with Kwik-Sil (World Precision Instruments, Sarasota, FL) before suturing the skin incision. Ketofen (2.5 mg kg−1, i.p.) and Carprofen (2.5 mg kg−1, i.p.) were administered to reduce inflammation and provide analgesia. Each animal was allowed to recover individually in a heated home cage until fully mobile and were then returned to social housing.

2.3.Implantation of GRIN lens and DBS electrode

Since the electrodes used for application of electrical stimulation to the STN and the GRIN lens needed to be embedded in the animal's dental cement headcap, both were inserted during the same surgical procedure. Detailed procedures for implantation of the GRIN lens, on its own, are well described in Resendez et al (2016) [48] and the GRIN lens implant location for striatal imaging was selected in accordance with Parker et al (2018) [43]. Although DBS electrode implant sites, electrode sizes and stimulation parameters have been described in rat models [49], much less work has been done in mice. For this reason, STN stimulation electrode sizes and the implant location were adapted from relevant rat studies [50, 51] based on the mouse brain atlas [52]. To ensure adequate time for viral transfection [43], two weeks after injection of viral vector and dopaminergic lesioning animals were prepared for a second surgery as described above. Burr holes were drilled above the dorsal striatum (ML 1.65, AP 1.0 from bregma) and STN (ML 1.45, AP −2.0 from bregma) (figure 2(C)). Three bone screws (Component Supply Company, Sparta TN) were placed to add structural support for the C&B Metabond (Parkell, Edgewood, NY) dental cement used to secure the implants. The dura was surgically opened through the STN burr hole using microdissection forceps to allow insertion of the electrode. A twisted bipolar teflon-insulated platinum DBS electrode (Plastics One, Roanoke, VA) with a 500 µm exposed tip, and contacts separated to 500 µm apart, was inserted to the STN (ML 1.45, AP −2.0, DV −4.7 from dura) at approximately 10 µm s−1 (figure 2(C)). Through the striatum burr hole, a 1 mm diameter column of tissue above the dorsal surface of the striatum was then aspirated to clear a path for lens implantation. To prevent aspirating deeper than the intended target, a blunt 27-gauge needle was bent 2.1 mm from the tip, which is approximately the depth from the surface of the skull to the top of the dorsal striatum, and used to aspirate tissue until the white matter of the corpus collosum was visually identified through a Leica M320 surgical microscope (LEICA, Wetzlar, Germany). A small portion of white matter was then carefully removed through aspiration to expose the dorsal surface of the striatum for imaging while minimizing tissue damage. A 4 mm long, 1 mm diameter GRIN lens (Inscopix, Palo Alto, CA) was then inserted through the striatal burr hole to a depth of −2.35 mm from dura using a custom-built lens holder (figure 2(C)). The custom-built lens holder was fabricated from a micropipette tip cut so that ∼500 µm of the lens was securely held. Kwik-Sil was used to seal both burr holes following implantation of the GRIN lens and DBS electrode. A headbar was mounted so that it extended laterally from the animal's skull contralateral to the implants to allow head-fixing of the animal while installing the microscope baseplate (figure 2(D)). C&B Metabond was used to secure the headbar, DBS electrode, and GRIN lens to the skull forming a headcap. The lens surface was protected using a custom-made plastic cap made from the bottom tip of a microcentrifuge tube attached with Kwik-Cast (World Precision Instruments, Sarasota, FL). The same post-operative approach from the previous section was followed.

2.4.Microscope baseplate installation (baseplating)

In order to perform calcium imaging during behavior with the nVoke miniature microscope (Inscopix, Palo Alto, CA), a mounting baseplate attached above the GRIN lens is needed [48]. Baseplates were permanently fixed to the headcap of the mouse at the position that maximized the number of active in focus neurons. Due to the locomotion dependence of striatal neural activity [43, 53, 54], the position was determined by visualizing active neurons in awake head-fixed mice. This procedure was completed two weeks after the GRIN lens implantation to allow for recovery (figure 2(A)). Mice were first head-fixed using the previously attached headbar and positioned on a custom-built running wheel to allow locomotion. Locomotion increases striatal neuron activity, making it easier to determine the mounting position that maximizes the number of in focus neurons [43, 53]. The microscope focusing turret (figure 1(A)) was initially set near the middle of its range to maximize the ability to correct for movement of the baseplate in either direction that can occur during dental cement curing. Next, with a baseplate attached, the nVoke microscope was positioned above the surface of the lens (figure 2(D)). The microscope was then leveled relative to the surface of the GRIN lens by ensuring the entire circumference around the edge of the lens was in focus. The excitation LED was then turned on to allow visualization of the fluorescent indicator [48]. The dorsoventral position of the miniature microscope was slowly varied over the area of tissue with the largest calcium signal until an imaging plane with in-focus active cells was found (figure 2(D)). The mediolateral and anteroposterior positions of the microscope were adjusted as necessary to maximize the number of active cells in the field of view. Once this position was found, the baseplate was attached to the headcap using C&B Metabond. Finally, the headcap was painted with black nail polish to prevent ambient light from filtering through the dental cement and contaminating the recordings (figure 2(D)).

2.5.Calcium imaging in anesthetized mice

Isoflurane was used to perform calcium imaging in anesthetized mice. The microscope was then attached to the baseplate, and the position of the microscope turret was adjusted to the imaging plane found during the baseplating procedure. This new turret position was recorded and used for all future imaging sessions. A series of 10-s duration, 130 Hz biphasic stimulation trains with 140 μs pulse width were applied in 1-min intervals using a Master-8 stimulator with Iso-Flex isolators (A.M.P.I, Jerusalem, Israel). The amplitude of the stimuli was increased until evoked changes in calcium signal were observed. Stimulation trains were then applied at frequencies of 30 Hz, 80 Hz, and 130 Hz and repeated three times [32]. These stimulation frequencies were selected based on previous studies in 6-OHDA lesioned rat models showing therapeutic effects at high frequency (80 Hz and 130 Hz) but not low frequency (30 Hz) stimulation [32]. Stimulation was triggered and synchronized with optical recordings using the digital I/O from the nVoke microscope system.

2.6.Open field calcium imaging during DBS

Mice were placed in a 45 cm by 45 cm open field arena (Med Associates, Fairfax, VT) with the miniature microscope and DBS electrodes connected. Animal movement was recorded with an overhead camera. The nVoke microscope sync signal provided through the nVoke digital IO box was used trigger to frame acquisition on the overhead camera. In non-lesioned animals without DBS implants, a 30-min recording was completed two days after mounting the microscope baseplate and was repeated weekly thereafter for four weeks. In 6-OHDA lesioned mice with DBS electrodes implanted, a DBS parameter selection session similar to the previously described session under anesthesia was completed four days after mounting the microscope baseplate. During the parameter selection session 1-min stimulation trains 130 Hz biphasic pulses (140 µs) were applied at 3-min intervals, while stimulation amplitude was increased to determine the stimulation threshold for evoking adverse effects. The most commonly observed adverse effect was abnormal motor activity or muscle contraction. Two 50-min recordings were then performed on days 6 and 8 after baseplating.

2.7.Identification of neural signals

Calcium imaging data were loaded into Inscopix Data Processing Software (IDPS) (Inscopix, Palo Alto, CA) for preprocessing prior to identification of neural signals via constrained non-negative matrix factorization for microendoscope data (CNMF-E) [55, 56]. All data were first spatially down sampled by a factor of two, which is common practice in order to decrease processing time for subsequent analyses [48, 57]. It was not necessary to use motion correction algorithms on data sets taken from anesthetized animals. However, calcium imaging data sets recorded in awake animals were then motion corrected with the Turboreg motion correction algorithm [58] as implemented in IDPS. To improve processing time and memory usage during the application of CNMF-E, data were downsampled within IDPS by an additional factor of three for a total effective downsampling of 6x. Data were then exported as TIF files from IDPS and loaded into Matlab® (Natick, MA). To identify neurons, the Matlab implementation of CNMF-E (https://github.com/zhoupc/CNMF_E) was applied to the data following the recommended procedure from Zhou et al (2018) [55] and computation was performed on the Neuroscience Gateway [59] high performance computing resource. Briefly, analysis was performed in patch mode using the largest possible patch sizes based on the available memory (128 GB) of the computational node. The ring model of background fluorescence [55] was used for all data sets. Neuron and ring sizes were selected based on the data set so that ring diameter was approximately 1.5 times the largest neuron diameters and described n Zhou et al (2018) [55].

2.8.Evaluation of calcium event rate

To demonstrate the utility of this combination of methods in the study of DBS in freely behaving mice, changes in the calcium event rate normalized to rest were calculated from data collected during open field behavior and analyzed using CNMF-E. The calcium event rate was calculated and normalized to the calcium event rate of the same animal at rest as described in Parker et al [43]. Briefly, the instantaneous calcium event rate for each frame was calculated as the total number of events, as output by CNMF-E, occurring in the frame. Frames were then binned based on locomotor velocity, as assessed using Ethovision XT (Noldus, Wageningen, The Netherlands). Calcium event rates were normalized to the mean event rate at rest to compare results between animals, which was defined as when the instantaneous velocity of the animal was less than 0.5 cm s−1 [53]. We then binned the calcium event rates into sets of values for which the locomotor velocity was the same to within 0.5–2.5 cm s−1, using finer bins at lower velocity and coarser bins at higher velocity [43]. For calcium event rate calculations during the application of DBS, the calcium event rates during ambulation (locomotor velocity > 0.5 cm s−1) were normalized to the mean event rat in the same animal at rest during unstimulated periods of the recording.

2.9.Perfusion and tissue preparation

Following euthanasia, transcranial perfusion was performed with 50 ml of 0.9% saline, followed by 50 ml of 4% paraformaldehyde in 0.1 M NaKPO4. Perfused brains were extracted, post-fixed overnight in 4% paraformaldehyde, and stored in 30% glycerol sinking solution. Cryosectioning with 40 μm slices was performed on a sliding microtome (Leica Biosystems, Wetzlar, Germany). Sections were stored in 0.1% Na Azide in 0.1 M phosphate buffer solution.

2.10.Histological evaluation of 6-OHDA lesion and stereotactic targeting

Coronal slices were rinsed in 0.01 M Phosphate buffered saline (PBS) with 0.2% Triton X-100 (PBS-Tx) and blocked in 10% normal goat serum in PBS-Tx for 1 h. Slices were then incubated with the primary antibody, anti-Tyrosine Hydroxylase (rabbit polyclonal, Abcam 1:4000) suspended in 10% normal goat serum (NGS). Incubation was performed overnight at 4 °C on a shaker. Each rinse was performed for two minutes and repeated three times. Following primary incubation, sections were given three successive 2-min rinses in PBS-Tx. Slices were then incubated in 10% NGS for 2 h at room temperature with the secondary antibody, goat anti-rabbit IgG conjugated to the fluorophore Alexa Fluor 647 (Thermo Fisher Scientific 1:200). Slides were then prepared to assess GRIN lens and STN lead placement based on the locations of the hypointense artifact left by removal of the implants before extraction of the brain. GRIN lens placement was visually confirmed to be within the dorsal striatum, a large and easily identifiable target. STN lead placement was confirmed by overlaying of a mouse atlas [52] on images of each slice showing the hypointense artifact left by the tip of the STN stimulation electrode. Animals were excluded from analysis if neither of the two stimulating electrode contacts were located within the STN as assessed through histological analysis. Following secondary incubation, sections were given three successive 2-min rinses with 0.1 M phosphate buffer, mounted onto subbed glass slides, and the coverslip was placed with ProLong Antifade Reagent containing DAPI (Thermo Fischer Scientific). Coronal slices were imaged using the Nikon Eclipse Ti microscope with Lumencor LED light source and Nikon Elements software. For assessment of the 6-OHDA lesion, tyrosine hydroxylase (TH) expression was quantified [60]. Images were obtained with a Tx Red filter cube and a shutter speed of 4 ms at 50% LED power. Thresholds were set to (30–255) after performing rolling ball background subtraction with a 50 pixel radius using ImageJ (National Institutes of Health, Bethesda, MD). TH positive cell bodies in the substantia nigra were manually counted as described in Winkler et al [61] and Santiago et al [62]. In the dorsal striatum, mean-pixel intensity of the TH signal was quantified using ImageJ [63] as the sum of pixel values (0–255)/number of square pixels. Striatal regions deformed by the GRIN lens tract as observed in the histology were not included in the analysis of mean-pixel intensity.

3.Results

The goal of this proof-of-principle study was to establish a methodological framework for overcoming experimental and data analysis challenges associated with combining electrical stimulation with calcium imaging in freely moving animals. The experimental protocol consisted of AAV9 injections to induce GCaMP6m expression (figure 2(A)), combined with placement of a GRIN lens (figure 2(B)), 6-OHDA lesioning (figure 2(A)), and placement of bipolar stimulating electrodes (figure 2(B)), first validated separately in different animal cohorts.

3.1.Histological validation of 6-OHDA lesioning, GCaMP expression, and implant positioning

The full experimental paradigm, consisting of 6-OHDA lesioning, AAV9 injection, GRIN lens implantation and STN stimulating electrode implantation, was performed on ten mice. Two mice were lost due to surgical complications, one due to GRIN lens damage that prevented imaging, and one animal that had insufficient GCaMP expression for imaging. An additional two mice were excluded from all analyses due to mistargeting of the stimulating electrode outside of the STN as assessed by post-mortem histology. These exclusion criteria are described in table 1. Expression of GCaMP6m calcium indicator, induced by AAV9.CAG.GCaMP6m.WPRE.bGHpA injection, was confirmed via histological analysis that showed green fluorescent cell bodies in the dorsal striatum (figure 3(B)). Most GCaMP expressing cells did not show any nuclear expression, which is an important indicator of cell health (figure S3 (available online at stacks.iop.org/JNE/18/026008/mmedia)) [48]. Dopaminergic lesioning via a unilateral 6-OHDA lesion, performed in the ipsilateral hemisphere, was confirmed by immunohistochemical labeling of TH followed by quantification of TH positive cells and mean pixel intensity (figure 3(A)). A significant decrease in dorsal striatal mean pixel intensity (figure 3(D), p < 0.05; Welch's unequal variance t-test), and SNc TH positive cells (figure 3(E), p < 0.05; Welch's unequal variance t-test) between the lesioned and non-lesioned hemispheres was observed.

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (3)

3.2.Chronic calcium imaging

Initial validation of calcium imaging within the striatum was performed in healthy mice without stimulation electrode implants (figure 4). A consistent number of cells, as identified by CNMF-E, were obtained in six recording sessions performed over 33 d across five animals (figure 4(B)). This indicates that recordings from the same brain area can be performed over time, however slight differences in the field of view were observed between recording sessions (figure 4(C)). Additionally, damage to the microscope during a recording session and the subsequent repair led to a slight change in the focal plane, including a rotation of 90°, between sessions (figure 4(C)).

3.3.Neural signal identification

Initial validation of the ability to record STN stimulation evoked responses in striatum prior to awake behaving experiments was performed in six anesthetized animals. Two animals did not exhibit stimulation evoked response within striatum; it was later verified via post-mortem histology that neither of the electrodes of the twisted bipolar pair were located in STN, and these animals were removed from the analysis. Stimulation evoked responses were observed in four anesthetized animals that were imaged during 10 s epochs of 30, 80 and 130 Hz stimulation. These epochs were separated by 1-min intervals to eliminate the residual effects from previous stimulations. This sequence was repeated three times in each animal. The striatum was quiescent while stimulation was turned off (figure 5(A)) under anesthesia, and only became active when STN stimulation was applied (figures 5(B)–(D)). STN stimulation activated a subset of in-focus cells within the striatum as well as caused out-of-focus changes in background fluorescence (figures 5(B)–(D)), which may originate from stimulation-evoked broad changes in cell activation. These stimulation-dependent out-of-focus signals are exemplified by changes in mean fluorescence within the field-of-view shown in figure 5(E). These out-of-focus changes and synchronous activation of multiple neurons confounded the analysis of calcium signals via standard data analysis techniques such as PCA/ICA, which identifies cells using differences in temporal characteristics (figure S5(B)). To quickly assess the performance of common algorithms in isolating activity of individual cells when in the presence of significant out of plane calcium activity induced by stimulation, simulated changes in background fluorescence based on a model of out-of-plane activation were added to an experimental data set (figure S1). The capability of common data analysis methods and spatial filtering techniques to identify spatially compact neurons and remove the simulated contamination were then qualitatively compared (figure S5).

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (5)

ROI analysis, PCA/ICA with or without spatiotemporal de-mixing, and CNMF-E [55, 56] were evaluated for their ability to extract well-defined cell bodies in the presence of real and simulated background fluorescence. Although ROI analysis allows for selection of well-defined cell bodies, it is a subjective technique and cannot separate cell activity from low spatial frequency background contamination. As a result, calcium traces extracted during electrical stimulation of the STN were nearly identical for all cells in the field of view (figure S5(A)). This suggests that the traces were primarily the results of background contamination and not from individual neural activity. Additionally, ROI analysis was not able to remove simulated background contamination (figure S5(A)). These results suggest that ROI analysis is not well suited for neuron identification from recordings obtained during electrical stimulation. Similar to ROI analysis, PCA/ICA [64] failed at uniquely identifying cells that exhibited synchronous firing during stimulation and was unable to completely remove artificial background contamination (figure S5(B)). Spatiotemporal de-mixing, which can be used to improve the identification of cells with PCA/ICA [64], did not result in significant improvements (figure S5(C)). Both ROI analysis and PCA/ICA were applied to the same data prefiltered using a spatial bandpass filter with cutoff frequencies chosen based on the size of cell bodies observed in the ΔF/F data (5 and 31 pixels). In both cases spatial filtering improved the rejection of artificial background contamination but did not completely eliminate the background contamination (figures S5(D)–(F)). In contrast, CNMF-E was able to identify individual cell bodies despite synchronous neural activity (figure S5(G)), does so in an objective manner, and is much less susceptible to low spatial frequency background noise. For this reason, we used CNMF-E for all subsequent data analysis presented in this manuscript.

3.4.Frequency dependence of STN electrical stimulation in anesthetized animals

A preliminary characterization of frequency dependent changes in STN stimulation evoked calcium responses within striatum was performed on recordings from four anesthetized mice with stimulation electrodes located in the STN that were described in the previous section. Although the striatum was observed to be quiescent under anesthesia (figure 5(A)), clear calcium activity suggestive of neuronal activation occurred with onset of STN stimulation at 30, 80, and 130 Hz (figures 5(B)–(D), Video S1). Additionally, the recruitment occurred in a frequency-dependent manner (figures 6(A)–(C)) with 80 and 130 Hz stimulation exhibiting a greater number of activated cells than stimulation at 30 Hz (figure 6(D), p < 0.05; Kruskal–Wallis one-way analysis of variance, Dunn's multiple comparison test). Despite the overall frequency dependence of neural activation, there was heterogeneity in the response of individual neurons to different stimulations as shown by figure 6(E). For instance, some cells only responded to stimulation at 80 Hz, but not 130 Hz (i.e. Figure 6(E), cell 2) or even showed heterogeneous responses to repeated stimulation at the same parameters (i.e. Figure 6(E), cell 4). The stimulation evoked behavior of specific cells did not necessarily depend on relative location of the cell in the field of view, with co-localized neurons showing different responses to similar parameters (figure 6(E)).

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (6)

3.5.Stimulation evoked behavioral and calcium responses

Two of the four mice in which anesthetized stimulation evoked recordings were performed also underwent awake-behaving imaging sessions in an open-field during stimulation (200 µs pulsewidth, 30 µA amplitude and 200 µs pulsewidth, 80 µA amplitude). In contrast to anesthetized recordings in the same animal, the striatal neural population was found to be highly active during open field behavior with increased activity during animal movement (figure 7(A), Video S2). This can be seen in the relationship between animal velocity (figure 7(A) top row) and cell activity shown on the raster plots (figure 7(A) second row) and calcium traces (figure 7(A) third row). The raster plot shown in the second row of figure 7(A) shows the calcium event timing for all cells in a representative data set and the traces show) and the raster of calcium traces on the third row of figure 7(A) shows the calcium activity for the 40 highest SNR cells in the data set. Significant differences in the relationship between the rate of calcium events and animal velocity were observed at both 30 Hz figures 7(B), (C); p < 0.0001 Kruskal–Wallis one-way analysis of variance, Dunn's multiple comparison test) and 130 Hz (figures 7(B), (C); p < 0.0001 Kruskal–Wallis one-way analysis of variance, Dunn's multiple comparison test).

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (7)

4.Discussion

Although there are several advantages to this combination of optical recordings and DBS in behaving pathological animals, achieving the complete experimental paradigm requires successful completion of a complicated set of procedures. All of the experiments outlined to demonstrate the utility of this method require the implementation of four separate components: (1) induction of calcium indicator, GCaMP6m, expression via a unilateral injection of an AAV9 viral vector into striatum (figures 2(A), (B)), (2) placement of a GRIN lens in the target recording location just above striatum (figures 2(A), (C)), (3) induction of a parkinsonian phenotype via unilateral injection of 6-OHDA into the substantia nigra pars compacta (SNc) (figures 2(A), (B)), and (4) placement of a bipolar stimulating electrode within the STN for application of electrical stimulation (figures 2(A), (B)). The complexity of troubleshooting these experimental components as well as the need for validation of each component in the context of the complete experimental paradigm is a significant hurdle to the adoption of this method for studying the effects of DBS. With the goal of enabling other researchers to adopt this combination of techniques to the study of neuromodulation therapies, here we describe our approach to implement and validate these experimental components to aid others in performing similar experiments.

4.1.Demonstration of utility of calcium imaging during STN DBS in parkinsonian mice

The fundamental goal of the experiments outlined in this methods paper was to demonstrate technical feasibility of the multicomponent surgical procedure, as well as demonstrate that the stimulation evoked responses in a commonly explored downstream structure (striatum) of a traditional DBS target (STN) varied as a function of behavioral state (anesthetized, awake sedentary, awake moving). These data were intended to underscore that the combined experimental preparation can yield unique information that may be useful in the study of DBS mechanisms in the future, but were not intended at this time to make any definitive conclusions about the therapeutic mechanisms of STN DBS to treat parkinsonian symptoms.

As a first exploration of the capabilities of single photon calcium imaging to assess the effects of DBS, we looked at the frequency dependence of evoked neural activity in anesthetized mice. Other studies have shown that electrical stimulation excites neural elements in a frequency dependent manner [65] and that therapeutic responses to neuromodulation are highly dependent on stimulation frequency [66]. For example, therapeutic efficacy for STN DBS in human patients is typically achieved with high frequency stimulation in the range of 120–180 Hz [67]. The population of neurons activated by stimulation during anesthesia was a small subset of the neurons identified during unstimulated awake behaving recordings (figures 6(A)–(C)). This sparse activation is consistent with other work using optical techniques showing sparse neural activation around a stimulation electrode [65, 68]. An increase in the number of cells activated at 80 and 130 Hz stimulation was observed compared to stimulation at 30 Hz (figure 6(D)). In anesthetized optical recordings, heterogeneous changes in neural activation within striatum were observed, with different cells that were near each other in the microscope field of view responding to stimulation at different frequencies (figure 6(E)). This heterogeneity may be due to differences in response of specific cell types. The heterogeneity could also be the result of subtle changes in stimulation evoked local neuronal/non-neuronal activity as a function of distance from the bipolar electrode, leading to varied responses at a distal point in the connected circuit.

To illustrate the technical feasibility of performing optical recordings in striatum while stimulating STN in an awake behaving pathological model, we performed a series of recordings with 10-min periods of 30 Hz and 130 Hz electrical stimulation interleaved by 10-min periods without stimulation. In behaving mice, the striatum was found to be much more active (figure 7(A)) than under anesthesia (figure 5(A)). Additionally, neuronal activity within the striatum was found to increase with movement of the mouse, as assessed by animal velocity (figures 7(A)–(B)). In contrast to STN stimulation in the anesthetized state which increased observed activity in striatum (figure 6), in the two animals in which anesthetized and awake recordings were performed STN stimulation during minimally constrained behavior decreased the activity in striatum (figure 7). Given the low number of animals we cannot draw any definitive conclusions about DBS mechanism across an entire population; however, these data suggest that the downstream effects of DBS may also depend on behavioral inputs to the same circuitry, thus underscoring the need for recording technology compatible with unrestricted behavioral experiments during DBS. Additionally, recording from genetically defined sub-populations of cells using calcium imaging would enable studies of neuromodulation effects in the context of specific neuronal cell types, such as D1 and D2 medium spiny neurons that form the primary outputs of the striatum [43].

4.2.Technical challenges toward implementation of the complete experimental protocol

The complex nature of these proof of concept experiments led to successful stimulation and imaging in 40% of the animals, with primary failure points being anesthesia related complications during surgery (20%), lens damage during group housing of the animals (10%), insufficient GCaMP expression (10%), and failure to place the STN stimulation electrode within the target structure (20%). These failure points can be improved with practice and some simple modifications to the experimental procedures. However, with multiple cumulative points of failure across different components of this procedure, it is particularly important to minimize failures in order to obtain a practical level of experimental yield. To accomplish this, we recommend optimizing each component of the surgical procedure in isolation to minimize surgical time and complications prior to attempting the components in combination. By optimizing each component in parallel, we were able to complete the first cohort of animals with the entire experimental paradigm approximately two months after beginning this project.

The DBS implant procedure has a high rate of failure due to the difficulty targeting small brain nuclei in the mouse model. For this reason, it is important to practice and optimize the targeting of the DBS implant before combining it with the other components of the overall procedure. Since, validation of electrode location cannot be obtained until histological verification is performed, a large amount of time could be spent performing experiments on animals that will be excluded from the analysis due to mistargeting of the electrode. One step that we have since taken to improve targeting is switching to the use of custom electrodes made from platinum/iridium wire (A-M Systems) instead of the platinum electrodes from PlasticsOne used in these studies. At the electrode sizes used in these experiments (75 µm diameter wire), platinum/iridium electrodes are much stiffer than pure platinum electrodes; in our experience they were less likely to deviate from the target trajectory during insertion. Another component that should be independently validated before attempting implantation of the GRIN lens and subsequent imaging is that GCaMP expression in the target location is sufficient and does not show nuclear expression that is indicative of toxicity [48]. Appropriate GCaMP expression is a critical aspect of successful imaging that can be easily checked before imaging in genetic lines or with AAV induced models. If using an AAV, expression can be adjusted by adjusting the titer of the virus, which may be helpful for optimizing for a specific target location.

An avoidable point of failure in our experiments that can be addressed during the surgical procedures was protection of the GRIN lens from damage during the time between implantation of the lens and baseplating the animal. During the experiments presented in this manuscript, we protected the GRIN lens with a protective plastic cap made from the end of a microcentrifuge tube and attached with Kwik-Cast adhesive. We have since switched to using dental cement to hold the protective cap to the animals headcap for a more secure connection. Whatever method is selected, it should be optimized prior to attempting the complete experimental paradigm to prevent animal losses at this stage.

The implementation of microendoscope optical recordings and simultaneous stimulation through implanted electrodes needs to be carefully planned in the context of specific behavioral experiments, as the connection to instrumentation can both constrain behavior as well as place strain on the connectors and the headcap itself. In our experiments, for instance, individual recording sessions were limited to 10 min in 6-OHDA lesioned mice in order to prevent tangling of the microscope and stimulation wires due to biased rotational behavior of the lesioned animals. In the future this recording time will be extended with the addition of a commutator [6971]. Appropriate control of the wires and use of a commutator to enable unrestricted behavior of the animal will be critical to rigorous studies of behavioral changes during the application of DBS, where additional wires needed for electrical stimulation can impose additional constraints on behavior of the mouse over the miniature microscope alone.

Other studies using single and two photon microscopy in behaving animals have shown stable longitudinal recordings in excess of one month [4346]. These data suggest that longitudinal recording from the same cell population over weeks of neuromodulation therapy may be possible. Neuromodulation therapies for some neurologic and psychiatric conditions, such as depression and epilepsy can take months to show therapeutic effect [11, 3442]. Thus, the capability to longitudinally record from the same set of cells via calcium imaging in a deep brain regions over weeks to months is important to enable the in vivo study of plasticity in neuromodulation therapies that can be difficult via electrophysiology or functional imaging methods. In contrast to electrophysiological recordings where highly similar waveforms measured across time from different neurons in the vicinity of the recording electrode can make it difficult to guarantee the tracking of a single-unit from recording obtained on different days [24, 25], the ability to directly visualize neuron somas in optical recordings and use their relative locations as landmarks may make it easier to confidently track the same neuron over time [72]. In figure 4(B), we demonstrated the ability to record cells during six recording sessions over the course of a month. However, slight differences in the field of view can be seen between recording sessions as well as a rotation of the field of view caused by the repair of the microscope being used in the experiments between days 0 and 12. We attempted to perform tracking of individual cells between recording session in the data from these experiments using the cell tracking algorithm presented in Sheintuch et al (2018). However, this was not successful due to inconsistent placement of the microscope leading to changes in the field of view between sessions. For this reason, although it is likely possible to align cells over longer periods of time up to weeks or months [4346] in animals undergoing neuromodulation therapies, it is important to note that these analysis require careful placement of the microscope to obtain the same field of view between recording sessions. In practice this proved to be difficult, however the process may be improved by new iterations of microscope technology that include electronic focusing capabilities [73].

4.3.Neural signal identification techniques during electrical stimulation

Unlike two-photon microscopy, which is robust to changes in activity outside of the focal plane, single photon microscopy can be easily contaminated by out-of-focus changes in neural activity. Although these changes in activity may not significantly impact the analysis of neural activity during some behavioral paradigms, they can have a significant effect when electrical stimulation is applied. Therefore, attention should be paid to application of existing analysis techniques to the study of neuromodulation paradigms, which may introduce non-physiological changes in neural activity. Initially, we applied PCA/ICA, a commonly used analysis technique for calcium imaging data, to identify cell activity in recordings obtained in behaving animals. Using PCA/ICA we observed artifactual high correlation between calcium traces recorded from nearby cells and were not able to distinguish overlapping cells bodies (figure S4), a limitation that have been observed by other recent studies [55, 74]. This led us to perform a qualitative analysis of different algorithms to remove artificially added stimulation induced background fluorescence changes from data recorded in anesthetized animals (figure S5). Our data suggests that ROI analysis and PCA/ICA, which are commonly applied algorithms for identifying neural signals in calcium imaging recordings, were not suitable for isolating calcium traces from in focus neurons from the artificially added out-of-focus contamination. Compared to ROI analysis and PCA/ICA, even with bandpass filtering of the data prior to analysis, CNMF-E was better able to isolate calcium traces from in focus neurons. This suggests that CNMF-E is better suited analysis of data obtained during the application of neuromodulation therapies. These results are in agreement with other comparisons of CNMF-E to PCA/ICA in other contexts that have been recently published [55, 74].

Single photon microscopy has been important for obtaining results in deep brain regions by imaging through a GRIN lens in freely behaving animals [45, 48], however two photon-microscopy can also been performed through a GRIN lens [43, 75]. The minimal out-of-focus fluorescence of two photon microscopy could avoid many of the analysis issues described in this section and has other benefits such as imaging multiple indicators [43], which has not yet become common for single-photon head-mounted systems [76]. The disadvantage of using two-photon microscopy is that less neurons can be simultaneously imaged, and it is generally required to head-fix animals, which can affect the outcomes of behavioral experiments [77].

4.4.Validation of the pathological model and DBS therapy in the context of the GRIN lens implant

In order to perform a mechanistic study to isolate the mechanisms of STN DBS therapy with appropriate scientific rigor in the mouse model, there are a number of potential confounds that must be addressed, including: (1) establishing the therapeutic efficacy of DBS to alleviate pathological symptoms in the mouse model without the complication of an invasive indwelling GRIN lens, (2) determining the impact of the indwelling GRIN lens on normal and pathological behavior, and (3) assessing the impact of the indwelling GRIN lens on the therapeutic function of DBS.

Single-photon calcium imaging via a head-mounted microscope is primarily performed in mouse models due to the availability of genetic lines and more extensive experience with induction of expression with viral vectors that can be leveraged to express calcium indicators in specific cell types. In contrast, historic studies of neuromodulation therapies usually utilize rats or large animal models in order to increase space for the implantation of electrodes, improve targeting of small neural structures, and reduce the difference in sizes of electrodes and brain nuclei compared to the human therapies. Although many pathological models for diseases treated by DBS have been well established in mouse models, the electrode configuration and parameters that best mimic clinical DBS in mouse animal models are not well understood [49, 78]. Therefore, the therapeutic efficacy of DBS applied to clinically relevant targets in these models needs to be validated before rigorous studies into the mechanisms of DBS can be performed. We have begun this work for STN-DBS in a 6-OHDA mouse model of Parkinson's disease, with preliminary data provided in the Supplemental Methods as a frame of reference (figure S2).

Another important consideration that needs to be further validated is the effect of tissue aspiration and GRIN lens implantation on the mechanisms underlying the effects of neuromodulation therapies [79]. For example, this procedure disrupts tissue within the motor cortex, striatum, and other structures which may be critical to the therapeutic effects of DBS. There is growing evidence that the trauma due to the implantation of electrodes in or on the brain, and the trauma due to the associated surgical procedure, can induce deficits in motor function and other outcomes. These deficits may only be apparent when more sophisticated measures of motor function are used [79]. Similarly, there is evidence to suggest the presence of a comparatively small chronic indwelling electrode may impact ion channel expression in nearby tissue out as far as 200 microns [80]. For this reason, it is paramount to understand and anticipate potential confounds created by the GRIN lens implant on both normal and pathological behaviors, as well as response to therapeutic interventions. To some extent the lens implant access route can be optimized to minimize influence on pathways putatively associated with the behavior in question, pathological influence on that behavior, and circuitry hypothesized to be engaged in DBS therapeutic effect. DBS therapies are increasingly thought to act through circuit mechanisms that rely on activation of tracts of passage near the electrode in addition to local effects. For instance, one of the current leading theories for the mechanism of STN DBS to treat PD is that DBS disrupts pathological synchrony in the basal ganglia-thalamo-cortical motor circuit through antidromic activation of motor cortex [81, 82]. In general, disruption of these pathways due to damage caused by aspiration and insertion of the GRIN lens has the potential to disrupt or modify the pathological behaviors being studied or the therapeutic mechanism of DBS.

To address these issues for the 6-OHDA mouse model of Parkinson's Disease cohorts directly comparing normal behavior with and without a GRIN lens implant in the target recording area, as well as comparing DBS effects on pathological behavior in animal cohorts with and without a GRIN lens implant, must be completed in future studies. It is important to note that changing the route of access for the GRIN lens intended to image the same target could alter pathological behavior and DBS therapeutic efficacy; therefore, any change to the GRIN lens implantation route would need to be assessed with additional cohorts.

5.Conclusions

Optical imaging technologies such as single and two-photon imaging of calcium indicators as surrogates of neural activity have been widely adopted by neuroscientists for the ability of these systems to record from hundreds of single cells with cell-type specificity provided by genetically encoded indicators. These techniques are particularly well suited for studying the spatial dynamics in neural activity that orchestrate healthy behavior and the transition to maladaptive dynamics in a disease state [43]. Single photon microscopy via head-mounted microscopes has the distinct advantage of enabling calcium imaging in freely behaving animals and has already been utilized to show how cell-type specific spatial and temporal dynamics within the striatum break down in PD and are restored with pharmacological treatment [43]. Although this study describes preliminary data on the application of optical imaging, and specifically head-mounted miniature microscopy, for the study of electrical stimulation of the STN, these data represent only one example of the myriad of applications for this technology in the study of the neuronal effects of neuromodulation.

Acknowledgments

This work was supported by the National Institutes of Health NINDS R01 NS084975, and The Grainger Foundation.

Author contributions

JKT, AJA, ENN, JLL, and KAL, designed the experiments. JKT, AJA, ENN, and DC performed the experiments. JKT, AJA, ENN, JMT, and NAK analyzed the data. JKT, AJA, ENN, JLL, and KAL wrote the manuscript. TDK, MS, JJN, SLO, JGP, provided additional materials or expertise needed to perform the experiments or analyze the data. JLL and KAL supervised all aspects of the work.

Conflict of interest statement

DC, MS, JJN, and SLO are paid employees of Inscopix Inc. KAL is a paid consultant for Galvani Bioelectronics, Neuronoff, NeuroOne & Cala Health. KAL is also a paid member of the Scientific Advisory Boards for Cala Health, Neuronoff, Battelle, BlackFynn & NeuroOne. None of the above financial interests overlaps with the data presented in this paper.

Calcium imaging in freely moving mice during electrical stimulation of deep brain structures (2024)

References

Top Articles
Latest Posts
Article information

Author: Patricia Veum II

Last Updated:

Views: 6418

Rating: 4.3 / 5 (44 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Patricia Veum II

Birthday: 1994-12-16

Address: 2064 Little Summit, Goldieton, MS 97651-0862

Phone: +6873952696715

Job: Principal Officer

Hobby: Rafting, Cabaret, Candle making, Jigsaw puzzles, Inline skating, Magic, Graffiti

Introduction: My name is Patricia Veum II, I am a vast, combative, smiling, famous, inexpensive, zealous, sparkling person who loves writing and wants to share my knowledge and understanding with you.